3LD2804-0TK53 – Switch Disconnector

Main Product > > Siemens Industrial Control

3LD2804-0TK53SENTRON, Switch disconnector 3LD – 3LD2804-0TK53
emergency switching-off switch, 3- pole, Iu: 125 A, operating power / at AC-23 A 400 V: 45 kW, front-mounted, rotary operating mechanism, Red / yellow, 4-hole mounting of the handle

Technical Specification

Model
product brand name SENTRON
product designation Switch disconnector
design of the product EMERGENCY-STOP switch
display version for switch position indicator manual operation 1 ON – 0 OFF
type of switch front mounted
design of the actuating element Short rotary knob
color of the actuating element red
design of handle rotary operating mechanism, red/yellow
type of the driving mechanism motor drive No
General technical data
number of poles 3
size of switch disconnector 4
mechanical service life (operating cycles) typical 100.000
electrical endurance (operating cycles)
● at AC-23 A at 690 V 6.000
operating frequency maximum 50 1/h
degree of pollution 3
Voltage
insulation voltage rated value 690 V
6 kV
surge voltage resistance rated value 6 kV
operating voltage
● at AC rated value 690 V
operating frequency rated value
● minimum 50 Hz
● maximum 60 Hz
Protection class
protection class IP IP65
degree of protection NEMA rating 1, 3R, 4X, 12
protection class IP on the front IP65
Dissipation
power loss [W] for rated value of the current at AC in hot operating state per pole 12 W
Main circuit
operational current
● at AC-21 at 690 V rated value 125 A
● at AC-21 A at 240 V rated value 125 A
● at AC-21 A at 400 V rated value 125 A
● at AC-21 A at 440 V rated value 125 A
● at AC-23 A at 400 V rated value 80 A
operating power
● at AC-23 A at 240 V rated value 22 kW
● at AC-23 A at 400 V rated value 45 kW
● at AC-23 A at 440 V rated value 45 kW
● at AC-23 A at 690 V rated value 37 kW
● at AC-3 at 240 V rated value 22 kW
● at AC-3 at 400 V rated value 37 kW
● at AC-3 A at 690 V rated value 30 kW
Auxiliary circuit
number of CO contacts for auxiliary contacts 0
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
operating voltage of auxiliary contacts at AC maximum 500 V
continuous current of the auxiliary contact rated value 10 A
insulation voltage of the auxiliary switch rated value 500 V
Suitability
suitability for use main switch Yes
suitability for use switch disconnector Yes
suitability for use EMERGENCY OFF switch Yes
suitability for use safety switch Yes
suitability for use maintenance/repair switch Yes
Product details
product feature can be locked into OFF position Yes
accessories
product extension optional
● motor drive No
● voltage trigger No
number of connectable NC contacts for auxiliary contacts attachable maximum 3
number of connectable NO contacts for auxiliary contacts attachable maximum 3
number of connectable CO contacts for auxiliary contacts attachable maximum 0
number of bracket locks maximum 3
hasp thickness of the bracket locks 4 … 8 mm
Short circuit
conditional short-circuit current with line-side fuse protection
● at 690 V by gG fuse rated value 20 kA
let-through current with closed switch
● at 240 V for combination switch + gG fuse maximum 10 kA
● at 440 V for combination switch + gG fuse maximum 10 kA
● at 690 V for combination switch + gG fuse maximum permissible 10 kA
I2t value with closed switch
● at 240 V for combination switch + gG fuse maximum 104 kA2.s
● at 440 V for combination switch + gG fuse maximum 104 kA2.s
● at 690 V for combination switch + gG fuse maximum 104 kA2.s
design of the fuse link
● for short-circuit protection of the main circuit required fuse gL/gG: 125 A
● for short-circuit protection of the auxiliary switch required fuse gL/gG: 10 A
operational current of upstream fuse rated value 125 A
according UL
operational current at AC according to UL 508/UL 60947-4-1 rated value 125 A
operating voltage at AC at 50/60 Hz according to UL 508/UL 60947-4-1 rated value 600 V
active power [hp] at AC at 480 V according to UL 508/UL 60947-4-1 rated value 75
active power [hp] at AC at 600 V according to UL 508/UL 60947-4-1 rated value 100
short-time withstand current (SCCR) at 600 V according to UL 508/UL 60947-4-1 10 kA
continuous current of upstream fuse according to UL rated value 200 A
type of fuse according to UL RK5
Connections
AWG number as coded connectable conductor cross section solid maximum
1
12
type of connectable conductor cross-sections for copper conductor
● solid 1x (4…50mm²)
● finely stranded with core end processing 1x (4…35mm²)
● stranded 1x (4…50mm²)
type of connectable conductor cross-sections for auxiliary contacts
● solid lateral auxiliary switch 2x (0,75 … 2,5mm²), 1x 4mm²; front auxiliary switch 1x (0,75 … 2,5mm²)
● finely stranded with core end processing lateral auxiliary switch 2x (0,75 … 1,5mm²), 1x 2,5mm²; front auxiliary switch 1x 2,5mm²
● stranded lateral auxiliary switch 2x (0,75 … 2,5mm²), 1x 4mm²; front auxiliary switch 1x (0,75 … 2,5mm²)
type of electrical connection
● for main current circuit box terminal
● for auxiliary contacts connection terminals
Mechanical Design
height 106 mm
width 90 mm
depth 112.5 mm
type of device fixed mounting
fastening method Built-in unit fixed-mounted version
fastening method
● 4-hole front mounting Yes
● front mounting with central attachment No
● rail mounting No
net weight 480 g
Environmental conditions
ambient temperature during operation
● minimum -25 °C
● maximum 55 °C
ambient temperature during storage
● minimum -25 °C
● maximum 55 °C